| MILLENNIUM
SERIES Power Inverters |
| Environmentally
Friendly, Quiet, Reliable AC Power |
|
|
|
| Output Voltage (VAC) |
120 RMS ± 5% |
| Output Frequency |
60 Hz ± 0.05% |
| Output Waveform |
Quasi-sine wave, with proprietary
waveform stabilizer circuit |
| Input Voltage (VDC) |
11 to 14 |
| Operating
Temperature |
-20° to 40°C (0° to 104°F) |
| Efficiency |
Up to 93% |
|

|
 |
 |
 |
|
R4 Option |
|
Other Design Features:
- Large TO-247 MOSFET technology
- Thermally-controlled cooling fan
- GFCI outlet protection
- Enclosed AC and DC cable connections with
strain relief
- Remote ON/OFF switch hookup
- LED indications of Inverter power, Low
battery, Overload, and High temperature
- Battery voltage indicator with push-to-test
- Optional Battery Charger "B3" and Transfer Relay
"T"
- Optional Remote Panel "R" with LED
indication of External power, Inverter power, Overload, and High temperature
- Optional
Remote Panel “R4” with Liquid Crystal Display (11 operating & 12
troubleshooting messages)
|
Unit Protection:
- Automatic electronic short circuit/overload protection
- Automatic high temperature shutdown
- Output circuit breakers
Battery Protection:
- Automatic low battery shutdown at 10.5 volts (with in-rush delay)
|
|
| MODEL NUMBER |
12X16U |
12X20U |
12X25U |
12X30U |
12X36U |
| Documentation |
 |
| Output Power (Watts
Cont.) |
1,600 |
2,000 |
2,500 |
3,000 |
3,600 |
|
Output Current (Amps AC) |
Up to
13 |
Up to
17 |
Up to
21 |
Up to 25 |
Up to 30 |
|
Peak Output (Amps AC) |
55 |
70 |
80 |
90 |
90 |
|
Output Rating (Horsepower) |
1/3 |
½ |
¾ |
1 |
1½ |
|
Input Current (Amps DC) |
Up to
160 |
Up to
200 |
Up to
250 |
Up to
300 |
Up to 360 |
|
Weight (lbs.) |
40 |
44 |
49 |
53 |
58 |
|
Dimensions (in.)
LxWxH |
15¾ x 11½ x 7¾ |
| BATTERY CHARGER "B3" |
3
step charger with automatic conditioning; Temperature compensated output
voltage; selectable between wet and sealed lead acid batteries; selectable
between small and large battery banks |
|
Output Current (Amps DC) |
75 |
100 |
130 |
140 |
140 |
|
Input Current (Amps AC) |
Up to 16 |
Up to 21 |
Up to 26 |
Up to 28 |
Up to 28 |
| TRANSFER RELAY "T" |
Fail-safe
shore power Transfer Relay |
| Current Rating (Amps
AC) |
30 |
| Transfer Time
(milliseconds) |
Less than 16 typical |
|
Usage: Any 120 VAC, 60 Hz, product within the inverters power
rating that does not require a pure sine waveform.
Warranty: Full year parts and factory labor (with Advance Replacement
Program) |
|