| HIGH
VOLTAGE Power Inverters |
| Environmentally
Friendly, Quiet,
Reliable, AC Power |
|
| Output Voltage (VAC) |
120 ±5% |
| Output Frequency |
60 Hz ± 0.02% |
| Output Waveform |
Quasi-sine wave, with
waveform stabilizer |
| Input Voltage (VDC) |
190 to 300 with
maximum 5% ripple |
| Operating
Temperature |
-20° to 40°C (0° to 104°F) |
| Efficiency |
Up to 88% |
|
|
|
Other Design Features:
- NEMA type 12 enclosure
- LED indication of Inverter power, Low input
voltage, Overload, and High temperature
- Enclosed AC and DC cable connections
- Will hold a high voltage transient less than
600 volts with 200 amps flowing for 100 µseconds, up to 370 watt-seconds
peak absorption.
- Optional transfer relay "T"
|
Unit Protection:
- Automatic electronic short circuit/overload protection
- Automatic high temperature shutdown
- Output circuit breaker
Battery Protection:
- Automatic low power source shutdown at 190 volts (with in-rush
delay and automatic reset at 205 VDC)
|
|
| Model
Number |
ADI-250/1000 |
ADI-250/2000 |
| Specifications |

|
| Documentation |
 |
 |
| Output Power (Watts
Cont) |
1,000 |
2,000 |
|
Output Current (Amps AC) |
Up to 8 |
Up to 16 |
|
Peak Output (Amps AC) |
24 |
48 |
|
Output Rating (hp) |
˝ |
1 |
|
Input Current (Amps DC) |
Up to 5 |
Up to 10 |
|
Weight (lbs.) |
44 |
55
|
|
Dimensions (in.)
LxWxH |
15˝ x 16 x 7˝ |
| Transfer
Relay |
Smart relay with low input voltage disconnect |
| Current
Rating "T" |
30 amps AC with 30 amp output breaker |
| Transfer
Time (ms) |
65 typical |
|
Usage: Any 120 VAC, 60 Hz, product within the inverters power
rating that does not require a pure sine waveform.
Warranty: Full year parts and factory labor |
|