Red LED Flash Power Backup
System |
| Output Voltage: |
120 VAC ±5 |
| Output Frequency: |
60 Hz ± 1% |
| Output Waveform: |
Quasi-sine wave, |
|
with waveform filter |
| Input Voltage:
(VDC) |
11 to 14 |
| Operating Temperature: |
-37° to 74°
C (-35° to 165° F) |
| Efficiency: |
Up to 90% |
|
 |
 |
|
Other Design Features:
- Output waveform smoothing
filter
- Thermally-controlled cooling fan
- Completely connectorized system
- LED indication of Inverter Power,
Low Input Voltage, and External Power.
|
Unit Protection:
- Automatic electronic short circuit/overload protection
- Automatic over temperature shutdown
- Output circuit breaker
Battery Protection:
- Automatic low battery shutdown at 10.5 VDC
|
|
|
| MODEL
NUMBER |
12/600Z1 |
| Documentation |
 |
| Output
Power (Watts Continuous) |
600 @ 25°C
(77°F), 400 @ 74°C (165°F) |
|
Output Current (Amps AC) |
Up to
5 |
|
Peak Output (Amps AC) |
12.5 |
|
Input Current (Amps DC) |
Up to
60 |
|
Weight (lbs.) |
13 |
|
Dimensions (in.) LxWxH |
12˝ x
6 x 5 |
| BATTERY
CHARGER |
|
| Output
Voltage (Volts DC) |
Regulated
and temperature compensated end of charge at 13.8 |
| Output
Current (Amps DC) |
Up
to 30 |
|
Input Current (Amps AC) |
Up
to 5 |
| TRANSFER
RELAY |
|
| Current
Rating (Amps AC) |
5 |
| Transfer
Time (milliseconds) |
6
typical |
|
Usage:
All NEMA, 170, or 2070 traffic equipment within the inverters power
rating that is not specifically designed for a pure sine waveform, such as a
solid state flasher relay.
Warranty:
Two year parts and factory labor |
|
Specifications are subject
to change without notice. |
| |
|