Home - Sensata Power Controls White Bear   Sensata Technologies Home Page
       

Contact Us

Home
 
HIGH VOLTAGE Power Inverters
Environmentally Friendly, Quiet, Reliable, AC Power
   
Output Voltage (VAC) 120 ±5% or 120/240 ±5% with the "D" Option
Output Frequency 60 Hz ± 0.02%
Output Waveform Quasi-sine wave with waveform stabilizer
Input Voltage (VDC) 56 to 80, 74 nominal
Operating Temperature -20° to 40°C (0°  to 104°F)
Efficiency Up to 88%
 

Other Design Features:

  • Patented construction and cooling methods
  • Thermally-controlled cooling fan
  • Remote ON/OFF switch hookup
  • Enclosed AC and DC cable connections
  • LED indication for Inverter power, Low input voltage, Overload, and High temperature
  • "D" Option 120/240 VAC output is standard on the 64/3600, 64/6000, and 64/8000 models.
  • Optional Transfer Relay "T" or "T1"

Unit Protection:

  • Automatic electronic short circuit/overload protection
  • Automatic over temperature shutdown
  • Output circuit breaker

Battery Protection:

  • Automatic low battery shutdown at 56 VDC (with in-rush delay)
Model Number 64/500 64/1000 64/2100 64/3600D 64/6000D 64/8000D
Specifications
Documentation  
Output Power (Watts Cont.) 500 1,000 2,100

    3,600 

6,000 8,000
Output Current (Amps AC) Up to 4 Up to 8 Up to 18 Up to 30 Up to 50 Up to 66
Peak Output     (Amps AC) 12 25 54 80 150 200
Output Rating (Horsepower) 1/3 ˝ 1 2 3 5
Input Current   (Amps DC) Up to 8 Up to 16 Up to 34 Up to 58 Up to 97 Up to 130
Weight (lbs.) 22 40 50 65 110 125
Dimensions (in.) LxWxH 15x8.2x7˝ 15˝ x 16 x 7˝ 16x17x10 18 x 20 x 12˝
Transfer Relay T T or T1
Current Rating "T" 15 amps AC with 15 amp output circuit breaker 30 amps AC with 30 amp output circuit breaker
Current Rating "T1" N/A                50 amps AC with 50                  amp output circuit breaker
Transfer Time (ms) 65 typical
Usage: Any 120 VAC or, with the "D Option", 240 VAC, 60 Hz, single phase product within the inverter’s power rating, unless designed specifically for a pure sine waveform
Warranty: Full year parts and factory labor