Other Design Features:
- High peak power output to start demanding loads
- Thermally-controlled cooling fan
- Enclosed AC and DC cable connections with
strain relief
- Battery Charger "B3" has automatic
power share to prevent tripping the shore power circuit breaker and an
automatic battery conditioning cycle to ensure optimum battery performance.
Automatic AC input voltage range sensing protects the inverter/charger by
allowing the charger connection only when safe AC shore power is available.
- The automatic fail-safe transfer feature
defaults to shore power when connected.
- Branch Breaker Options – "G option"
includes two @ 15A; "G1 option" includes two @ 20A and one @ 15A;
"G2 option" includes two @ 20A; "G3 option" includes three
@ 20A.
- Optional
LCD Remote Display Panel “R1” or "R4", that provides 11 operating &
12 troubleshooting
messages. NOTE: "R1" is used with those RVs that support a Master Disconnect
feature.
|
Unit Protection:
- Automatic electronic short circuit/overload protection
- Automatic high temperature shutdown
- Output circuit breaker
Battery Protection:
- Automatic low battery shutdown at 10.5 volts (with in-rush delay)
|
|
| 12V Input |
12X16 |
12X20 |
12X25 |
12X30 |
12X36 |
| Documentation |
 |
| Output Power (Watts
Cont.) |
1,600 |
2,000 |
2,500 |
3,000 |
3,600 |
| Output Current (Amps AC) |
Up to 13 |
Up to 17 |
Up to 21 |
Up to 25 |
Up to 30 |
|
Peak Output (Amps AC) |
55 |
70 |
80 |
90 |
90 |
| Output Rating (Horsepower) |
1/3 |
½ |
¾ |
1 |
1½ |
|
Input Current (Amps DC) |
Up to
160 |
Up to
200 |
Up to
250 |
Up to
300 |
Up to
360 |
|
Weight (lbs.) |
39 |
43 |
48 |
52 |
58 |
|
Dimensions (in.)
LxWxH |
14½
x 11½ x 7¾ |
15¾x11½x7¾ |
| BATTERY CHARGER |
3 stage; bulk, acceptance and
float, selectable between wet and sealed lead acid batteries, selectable between small and large battery banks |
| Output Current (Amps
DC) |
75 |
100 |
130 |
140 |
140 |
| Input Current (Amps AC) |
Up to 16 |
Up to 21 |
Up to 26 |
Up to 28 |
Up to 28 |
| TRANSFER RELAY |
Automatic
fail-safe shore power transfer |
| Current Rating (Amps AC) |
30 |
| Transfer Time
(ms) |
less
than 16
typical |
|
Usage: Any 120 VAC, 60 Hz, product within the inverters power
rating that does not require a pure sine waveform.
Warranty: One year parts and factory labor |
|