Other Design Features:
- Patented construction and cooling methods
- 16 bit, 16 MHz microprocessor control
- Thermally-controlled cooling fan
- KKK-A-1822E Certified
- GFCI protected receptacle
- AC hardwire hookup
- "A Option" provides GFCI protection
for the hardwire
output
- LED indication of External power, Inverter
power, Low battery, Overload, & High temperature
- Remote ON/OFF switch hookup
- Optional Battery Charger "B1" and
Transfer Relay "T" (not available on all models)
|
Unit Protection:
- Automatic electronic short circuit/overload protection
- Automatic high temperature shutdown
- Output circuit breaker
Battery Protection:
- Automatic low battery shutdown at 10.5 volts (with in-rush delay)
|
|
| Models |
12/1200N |
12/1800N |
12/2400N |
12/3000N |
| Documentation |
 |
 |
| Output Power
(Watts Cont.) |
1,200 |
1,800 |
2,400 |
3,000 |
|
Output Current (Amps AC) |
Up to
10 |
Up to
15 |
Up to
20 |
Up to
25 |
|
Peak Output (Amps AC) |
21 |
33 |
54 |
54 |
|
Input Current (Amps DC) |
Up to
120 |
Up to
180 |
Up to
240 |
Up to
300 |
|
Weight (lbs.) |
29 |
42 |
53 |
58 |
| Dimensions (in.)
LxWxH |
15 x
8¼ x 7½ |
15 x
16 x 7½ |
| BATTERY
CHARGER "B1" |
N/A |
Totally
Correct ®; automatic, regulated, temperature compensated voltage output,
State-of-Charge detector |
| Output Current (Amps
DC) |
N/A |
Up
to 85 |
N/A |
Up
to 105 |
|
Input Current (Amps AC) |
N/A |
Up
to 15 |
N/A |
Up
to 20 |
| TRANSFER
RELAY "T" |
N/A |
Smart
relay with low input voltage disconnect |
| Current
Rating (Amps AC) |
N/A |
30 |
| Transfer
Time |
N/A |
65
milliseconds (typical) |
|
Usage: Any 120 VAC, 60 Hz, product within the inverters power
rating
Warranty: Full year parts and factory labor
Refer
to the Utility/Work Truck section of the Dimensions web for other available
inverter models. |
| |
|