Other Design Features:
- Patented construction and cooling methods
- 16 bit, 16 MHz microprocessor control
- Thermally-controlled cooling fan
- Enclosed AC and DC cable connections (not on
24/400N)
- Remote ON/OFF switch hookup
- GFCI outlet protection
- LED indication of External power, Inverter power & Low
input voltage
- LED indication of Overload,
& High temperature (not on 24/400N)
- Battery voltage indicator with push-to-test
(not on 24/400N)
- Optional Battery Charger "B1" and
Transfer Relay "T" (not available on 24/400N model or 24/4800N) or
"T1" (not available on model 24/400N or 24/2200N)
- "D Option" 120/240 VAC output (not on 24/400N)
- Remote Control "R" (not on 24/400N)
|
Unit Protection:
- Automatic electronic short circuit/overload protection
- Automatic high temperature shutdown
- Output circuit breaker
Battery Protection:
-
Automatic low battery shutdown at 21 volts (with in-rush delay)
|
|
| 24V Input Models |
400N |
2200N |
3300N |
4800N |
4800DN |
5600DN |
| Documentation |
 |
 |
 |
| Output Power (Watts
Cont.) |
400 |
2,200 |
3,300 |
4,800 |
5,600 |
|
Output Current (Amps AC) |
Up to
3 |
Up to
18 |
Up to
28 |
Up to 40 |
Up to 23 |
|
Peak Output (Amps AC) |
9 |
55 |
80 |
110 |
140 |
|
Horsepower Ratings |
|
1 |
2 |
2 |
3 |
|
Input Current (Amps DC) |
Up to 20 |
Up to 110 |
Up to 165 |
Up to 240 |
Up to 280 |
|
Weight (lbs.) |
14 |
42 |
69 |
90 |
140 |
|
Dimensions (in.) LxWxH |
12˝x6x5 |
15˝x16x7˝ |
16x17x10 |
18x20x12˝ |
| BATTERY
CHARGER "B1" |
N/A |
Totally
Correct® battery charger technology; Automatic, regulated, temperature
compensated voltage output; Patented State-of-Charge detector. |
| Output Current (Amps
DC) |
N/A |
Up to 50 |
Up to 75 |
Up to
100 |
Up to
140 |
Up to
160 |
| Input Current (Amps
AC) |
N/A |
Up to 20
@ 120 VAC |
Up to 30
@ 120 VAC |
Up to 30
@ 120 VAC |
Up to 22
at 240 VAC |
Up to 26
@ 240 VAC |
| TRANSFER
RELAY |
N/A |
Smart
relay with low input voltage disconnect |
| Availability |
N/A |
T |
T or
T1 |
T1 |
T
or T1 |
| Current
Rating "T" |
N/A |
30
amps AC with 30 amp Output Circuit Breaker |
| Current
Rating "T1" |
N/A |
50
amps AC with 50 amp Output Circuit Breaker |
| Transfer Time |
N/A |
65
milliseconds (typical) |
|
Usage: Any 120 VAC, 60 Hz,
single phase product within the inverters power
rating.
Warranty: Full year parts and factory labor (with Advance Replacement
Program) |
| |
|